Commit b6967fa84c moved the functionality of managing cgroup devices
into a separate package, and decoupled libcontainer/cgroups from it.
Yet, some software (e.g. cadvisor) may need to use libcontainer package,
which imports libcontainer/cgroups/devices, thus making it impossible to
use libcontainer without bringing in cgroup/devices dependency.
In fact, we only need to manage devices in runc binary, so move the
import to main.go.
The need to import libct/cg/dev in order to manage devices is already
documented in libcontainer/cgroups, but let's
- update that documentation;
- add a similar note to libcontainer/cgroups/systemd;
- add a note to libct README.
Signed-off-by: Kir Kolyshkin <kolyshkin@gmail.com>
This commit does two things:
1. Consolidate StartInitialization calling logic into Init().
2. Fix init error handling logic.
The main issues at hand are:
- the "unable to convert _LIBCONTAINER_INITPIPE" error from
StartInitialization is never shown;
- errors from WriteSync and WriteJSON are never shown;
- the StartInit calling code is triplicated;
- using panic is questionable.
Generally, our goals are:
- if there's any error, do our best to show it;
- but only show each error once;
- simplify the code, unify init implementations.
Signed-off-by: Kir Kolyshkin <kolyshkin@gmail.com>
Do not set inheritable capabilities in runc spec, runc exec --cap,
and in libcontainer integration tests.
Signed-off-by: Kir Kolyshkin <kolyshkin@gmail.com>
Since LinuxFactory has become the means to specify containers state
top directory (aka --root), and is only used by two methods (Create
and Load), it is easier to pass root to them directly.
Modify all the users and the docs accordingly.
While at it, fix Create and Load docs (those that were originally moved
from the Factory interface docs).
Signed-off-by: Kir Kolyshkin <kolyshkin@gmail.com>
StartInitialization does not have to be a method of Factory (while
it is clear why it was done that way initially, now we only have
Linux containers so it does not make sense).
Fix callers and docs accordingly.
No change in functionality.
Also, since this was the only user of libcontainer.New with the empty
string as an argument, the corresponding check can now be removed
from it.
Signed-off-by: Kir Kolyshkin <kolyshkin@gmail.com>
What used to be godoc.org is now pkg.go.dev, and while the old URLs
still work, they might be broken in the future.
Updated badges are generated via https://pkg.go.dev/badge/
Signed-off-by: Kir Kolyshkin <kolyshkin@gmail.com>
Those are *always* /proc/self/exe init, and it does not make sense
to ever change these. More to say, if InitArgs option func (removed
by this commit) is used to change these parameters, it will break
things, since "init" is hardcoded elsewhere.
Remove this.
Signed-off-by: Kir Kolyshkin <kolyshkin@gmail.com>
This method was removed earlier by commit 097c6d7425,
but the documentation was not updated. Fix it.
Fixes: 097c6d7425
Signed-off-by: Kir Kolyshkin <kolyshkin@gmail.com>
These lists have been in the codebase for a very long time, and have
been unused for a large portion of that time -- specconv doesn't
generate them and the only user of these flags has been tests (which
doesn't inspire much confidence).
In addition, we had an incorrect implementation of a white-list policy.
This wasn't exploitable because all of our users explicitly specify
"deny all" as the first rule, but it was a pretty glaring issue that
came from the "feature" that users can select whether they prefer a
white- or black- list. Fix this by always writing a deny-all rule (which
is what our users were doing anyway, to work around this bug).
This is one of many changes needed to clean up the devices cgroup code.
Signed-off-by: Aleksa Sarai <asarai@suse.de>
`Init` on the `Process` struct specifies whether the process is the first process in the container. This needs to be set to `true` when running the container.
Signed-off-by: Andreas Stocker <astocker@anexia-it.com>
Cgroup namespace can be configured in `config.json` as other
namespaces. Here is an example:
```
"namespaces": [
{
"type": "pid"
},
{
"type": "network"
},
{
"type": "ipc"
},
{
"type": "uts"
},
{
"type": "mount"
},
{
"type": "cgroup"
}
],
```
Note that if you want to run a container which has shared cgroup ns with
another container, then it's strongly recommended that you set
proper `CgroupsPath` of both containers(the second container's cgroup
path must be the subdirectory of the first one). Or there might be
some unexpected results.
Signed-off-by: Yuanhong Peng <pengyuanhong@huawei.com>
Signed-off-by: Michael Crosby <crosbymichael@gmail.com>
Follow commit 3d7cb4293c ("Move libcontainer to x/sys/unix") and also
move the examples in README.md from syscall to x/sys/unix.
Signed-off-by: Tobias Klauser <tklauser@distanz.ch>
Add the import of nsenter to the example in libcontainer's README.md, as without it none of the example code works.
Signed-off-by: Steven Hartland <steven.hartland@multiplay.co.uk>
Add godoc links to README.md files for runc and libcontainer so its easy to access the golang documentation.
Signed-off-by: Steven Hartland <steven.hartland@multiplay.co.uk>
For example, the /sys/firmware directory should be masked because it can contain some sensitive files:
- /sys/firmware/acpi/tables/{SLIC,MSDM}: Windows license information:
- /sys/firmware/ibft/target0/chap-secret: iSCSI CHAP secret
Signed-off-by: Akihiro Suda <suda.akihiro@lab.ntt.co.jp>
This moves much of the documentation on contributing and maintainer the
codebase from the libcontainer sub directory to the root of the repo.
Signed-off-by: Michael Crosby <crosbymichael@gmail.com>