# KVTransferManager
|
||||
|
||||
A dedicated component for transferring KV Cache between Prefill and Decode nodes, supporting RDMA communication with ultra-low latency.
|
||||
|
||||
## Performance Benchmark
|
||||
|
||||
### KVTransferManager vs Mooncake Performance Comparison
|
||||
|
||||
### Test Scenario
|
||||
- **Hardware Configuration**:
|
||||
- Single Mellanox ConnectX-7 400G NIC (single port)
|
||||
- Tested with BATCH_SIZE = 1538 and block size = 1K - 256K
|
||||
- Single pressure thread (threads = 1)
|
||||
|
||||
- **Comparison Baseline**:
|
||||
- Mooncake performance measured using transfer_engine_bench from example directory
|
||||
- Same hardware configuration and test parameters applied to KVTransferManager
|
||||
|
||||
### Performance Results
|
||||
| Block Size | KVTransferManager | Mooncake | Performance Gain |
|
||||
|------------|-----------------|----------|------------------|
|
||||
| 1K | 10.67 GB/s | 1.54 GB/s | 6.9x |
|
||||
| 2K | 17.53 GB/s | 3.40 GB/s | 5.2x |
|
||||
| 4K | 28.85 GB/s | 6.95 GB/s | 4.2x |
|
||||
| 8K | 36.56 GB/s | 12.48 GB/s | 2.9x |
|
||||
| 16K | 41.73 GB/s | 23.42 GB/s | 1.8x |
|
||||
| 32K | 43.55 GB/s | 31.58 GB/s | 1.4x |
|
||||
| 64K | 44.46 GB/s | 38.39 GB/s | 1.2x |
|
||||
| 128K | 44.86 GB/s | 40.11 GB/s | 1.1x |
|
||||
| 256K | 45.01 GB/s | 40.71 GB/s | 1.1x |
|
||||
|
||||
Bandwidth Saturation Capability: Under multi-threaded high-pressure scenarios, both KVTransferManager and Mooncake can fully utilize the 400G network card bandwidth, achieving transmission performance close to the theoretical hardware limit (approximately 50 GB/s).
|
||||
|
||||
## Quick start
|
||||
|
||||
### Requirements
|
||||
|
||||
- Supported Architectures:
|
||||
Hopper GPUs
|
||||
Kunlun XPU
|
||||
Ampere GPUs (supported by enabling KVCACHE_GDRCOPY_FLUSH_ENABLE)
|
||||
### Dependencies Installation
|
||||
|
||||
#### Python Packages
|
||||
```bash
|
||||
pip install pyzmq pybind11[global]
|
||||
```
|
||||
|
||||
#### System Libraries (Linux)
|
||||
```bash
|
||||
# Ubuntu/Debian
|
||||
sudo apt-get install -y libibverbs-dev librdmacm-dev
|
||||
|
||||
# RHEL/CentOS
|
||||
sudo yum install -y libibverbs-devel librdmacm-devel
|
||||
```
|
||||
|
||||
#### Hardware Requirements
|
||||
- RDMA-capable network hardware (e.g. Mellanox NICs)
|
||||
- Supported GPU architectures: Hopper, Kunlun XPU, Ampere
|
||||
|
||||
#### Ampere Architecture Note
|
||||
To support Ampere GPUs, enable the environment variable KVCACHE_GDRCOPY_FLUSH_ENABLE.
|
||||
- What it does:
|
||||
Forces memory flushing after a GDRCopy write operation to ensure data consistency on the Ampere architecture. Here if KVCACHE_GDRCOPY_FLUSH_ENABLE is enable we trigger an RDMA read operation after the last RDMA write.
|
||||
- Why it’s needed:
|
||||
When the NIC delivers a completion to the CPU, it indicates that the data has reach the GPU. However, it doesn't mean that the GPU can read that data yet. To make sure the data has gone all the way down to the GPU memory and the GPU can read it, we need to perform a read.
|
||||
[NCCL Issue #683](https://github.com/NVIDIA/nccl/issues/683) |
|
||||
[NCCL Issue #1702](https://github.com/NVIDIA/nccl/issues/1702)
|
||||
Since the upper layer typically issues a cache arrival notification only after polling a Completion Queue Entry (CQE), this prevents the application from being notified before the data is actually written back to memory. Therefore, the potential race condition where the cache has not yet been flushed but the application assumes completion is considered a rare event in practice.
|
||||
- How to enable:
|
||||
export KVCACHE_GDRCOPY_FLUSH_ENABLE=1
|
||||
|
||||
### Development
|
||||
|
||||
```bash
|
||||
# Build and make symbolic links for SO files
|
||||
python setup.py bdist_wheel
|
||||
|
||||
pip install dist/*.whl
|
||||
```
|
||||
|
||||
## Environment Variables Configuration
|
||||
|
||||
### RDMA Settings
|
||||
| Variable | Default | Description |
|
||||
|----------|---------|-------------|
|
||||
| `KVCACHE_RDMA_GID_INDEX` | 3 | RDMA GID index |
|
||||
| `KVCACHE_RDMA_NICS` | - | RDMA NIC list, comma-separated (e.g., “mlx5_0,mlx5_1”), selects ib device based on gpu_index. This environment variable must be set. NICs are selected using modulo operation on gpu_index. |
|
||||
| `KVCACHE_IB_TIMEOUT` | 18 | InfiniBand communication timeout (14-31), where timeout = 4.096μs * 2^value (default 18 ≈ 1.07s).|
|
||||
| `KVCACHE_RELAX_ORDERING` | false | Enable RDMA relaxed ordering to improve performance in multi-GPU scenarios. Recommended when multiple GPUs share the same NIC to mitigate TX pause issues. |
|
||||
|
||||
### Network Settings
|
||||
| Variable | Default | Description |
|
||||
|----------|---------|-------------|
|
||||
| `KVCACHE_SOCKET_IFNAME` | auto | Network interface for socket comm (e.g. "eth0") |
|
||||
|
||||
### Debugging
|
||||
| Variable | Default | Description |
|
||||
|----------|---------|-------------|
|
||||
| `KVCACHE_DEBUG` | false | Enable debug logging |
|
||||
| `KVCACHE_DEBUG_FILE` | - | Debug log file path |
|
||||
| `KVCACHE_ERROR_FILE` | - | Error log file path |
|
||||
|
||||
### Performance Tuning
|
||||
| Variable | Default | Description |
|
||||
|----------|---------|-------------|
|
||||
| `KVCACHE_GDRCOPY_FLUSH_ENABLE` | false | Enable GDRCopy flush for Ampere GPUs |
|
||||
|
||||
|
||||
|
||||
# Set RDMA GID index
|
||||
export KVCACHE_RDMA_GID_INDEX=3
|
||||
|
||||
# Set RDMA IB Device List
|
||||
export KVCACHE_RDMA_NICS=mlx5_0,mlx5_1,mlx5_2
|
||||
|
||||
# Specify network interface
|
||||
export KVCACHE_SOCKET_IFNAME=eth0
|
||||
|
||||
# Enable debug mode
|
||||
export KVCACHE_DEBUG=1
|
||||
|
||||
# Set log files
|
||||
export KVCACHE_DEBUG_FILE=/var/log/kvcache_debug.log
|
||||
export KVCACHE_ERROR_FILE=/var/log/kvcache_error.log
|
||||
|
||||
|
||||
## Network configurations
|
||||
|
||||
kvcache transfer is fully tested with RDMA over Converged Ethernet (RoCE) networks. However, it is theoretically compatible with Infiniband as well.
|
||||
|
||||
For complete implementation details and advanced usage, please refer to the source code.
|
||||
|
||||
## Python API Reference
|
||||
|
||||
### RDMACommunicator Class
|
||||
|
||||
```python
|
||||
from rdma_comm import RDMACommunicator
|
||||
|
||||
# Constructor
|
||||
comm = RDMACommunicator(
|
||||
role, # Role ("prefill" or "decode")
|
||||
gpu_idx, # GPU device index
|
||||
port, # Communication port
|
||||
local_key_cache, # List of local key cache pointers
|
||||
local_value_cache, # List of local value cache pointers
|
||||
block_number, # Number of blocks
|
||||
block_bytes # Bytes per block
|
||||
)
|
||||
|
||||
# Methods
|
||||
comm.connect(dst_ip, dst_port) # Connect to target IP and port
|
||||
comm.is_connected(dst_ip, dst_port) # Check connection status
|
||||
comm.write_cache(
|
||||
ip, # Target server IP address
|
||||
port, # Target server port number
|
||||
local_block_ids, # List of local block IDs to transfer
|
||||
remote_block_ids, # List of remote block IDs to write
|
||||
layer_idx # Model layer index (for multi-layer models)
|
||||
)
|
||||
```
|
||||
|
||||
**Parameter Details**:
|
||||
|
||||
1. `role`:
|
||||
- "prefill": Prefill node role
|
||||
- "decode": Decode node role
|
||||
|
||||
2. `gpu_idx`:
|
||||
- GPU device index to use
|
||||
|
||||
3. `port`:
|
||||
- RDMA communication port number
|
||||
|
||||
4. `local_key_cache`/`local_value_cache`:
|
||||
- List of local KV cache pointers
|
||||
|
||||
5. `block_number`:
|
||||
- Number of cache blocks
|
||||
|
||||
6. `block_bytes`:
|
||||
- Bytes per cache block
|
||||
|
||||
**Example Usage**:
|
||||
|
||||
```python
|
||||
import numpy as np
|
||||
from rdma_comm import RDMACommunicator
|
||||
|
||||
# Initialize
|
||||
local_keys = [np.array([0]*1024, dtype=np.int64).ctypes.data] # Example key pointer
|
||||
local_values = [np.array([0]*1024, dtype=np.int64).ctypes.data] # Example value pointer
|
||||
|
||||
comm = RDMACommunicator(
|
||||
role="prefill",
|
||||
gpu_idx=0,
|
||||
port="12345",
|
||||
local_key_cache=local_keys,
|
||||
local_value_cache=local_values,
|
||||
block_number=1024,
|
||||
block_bytes=4096
|
||||
)
|
||||
|
||||
# Client connection
|
||||
comm = RDMACommunicator(
|
||||
role="prefill",
|
||||
gpu_idx=0,
|
||||
port="12345",
|
||||
local_key_cache=local_keys,
|
||||
local_value_cache=local_values,
|
||||
block_number=1024,
|
||||
block_bytes=4096
|
||||
)
|
||||
|
||||
if comm.connect("192.168.1.100", "12345"):
|
||||
print("Connection established")
|
||||
|
||||
# Write cache
|
||||
comm.write_cache(
|
||||
ip="192.168.1.100", # Target server IP
|
||||
port="12345", # Target server port
|
||||
local_block_ids=[0,1,2], # Local block IDs to transfer
|
||||
remote_block_ids=[3,4,5], # Remote block IDs to write
|
||||
layer_idx=0 # Model layer index (0 for first layer)
|
||||
)
|
||||
```
|
||||
|
||||
## Citation
|
||||
|
||||
If you use this codebase, or otherwise found our work valuable, please cite:
|
||||
Reference in New Issue
Block a user